Technische Daten - Übersicht: Unterschied zwischen den Versionen

Aus Wissen Wiki
Zur Navigation springen Zur Suche springen
Zeile 45: Zeile 45:
| width="45" style="font-size:90%" align="center"| '''[[Flächengewicht|Flächen-gewicht]]''' <br /> [kg/m²]
| width="45" style="font-size:90%" align="center"| '''[[Flächengewicht|Flächen-gewicht]]''' <br /> [kg/m²]
| width="35" style="font-size:90%" align="center"| '''[[Baustoffklasse|Brand- verh.]]''' <br /> [-]
| width="35" style="font-size:90%" align="center"| '''[[Baustoffklasse|Brand- verh.]]''' <br /> [-]
| width="35" style="font-size:90%" align="center"| '''Brand-kennz.''' <br /> <sub>n. [[VKF]]</sub>
| width="35" style="font-size:90%" align="center"| '''Brand-kennz.''' <br /> n. '''[[VKF]]'''
| width="88" style="font-size:90%" align="center"| '''Höchzugkraft''' <br /> <br /><sub>längs / quer</sub>
| width="80" style="font-size:90%" align="center"| '''Höchzugkraft''' <br /> [N/50 mm]<br /> <sub>längs / quer</sub>
| width="65" style="font-size:90%" align="center"| '''[[Dehnung]]''' <br /> <br /><sub>längs / quer</sub>
| width="60" style="font-size:90%" align="center"| '''[[Dehnung]]''' <br /> [%] <br /><sub>längs / quer</sub>
| width="98" style="font-size:90%" align="center"| '''[[Weiterreißwiderstand|Weiterreiß-widerstand]]''' <br /> <sub>längs / quer</sub>
| width="90" style="font-size:90%" align="center"| '''[[Weiterreißwiderstand|Weiterreiß-widerstand]]''' [N]<br /> <sub>längs / quer</sub>
| width="80" style="font-size:90%" align="center"| '''[[Temperaturbeständigkeit|Temperatur-beständigkeit]]''' <br /> [°C]
| width="80" style="font-size:90%" align="center"| '''[[Temperaturbeständigkeit|Temperatur-beständigkeit]]''' <br /> [°C]
| width="80" style="font-size:90%" align="center"| '''[[Alterungsbeständigkeit|Alterungs-beständigkeit]]''' <br /> [-]
| width="80" style="font-size:90%" align="center"| '''[[Alterungsbeständigkeit|Alterungs-beständigkeit]]''' <br /> [-]
Zeile 55: Zeile 55:
|colspan="10"| '''Luftdichtung innen'''  
|colspan="10"| '''Luftdichtung innen'''  
|-
|-
{{Tab Sp2-9 center|[[INTELLO]]|85|E|5.3|120 N/50 mm / 90 N/50 mm|50% / 45%|60 N / 60 N |-40&nbsp; -&nbsp; +80 |bestanden}}
{{Tab Sp2-9 center|[[INTELLO]]|85|E|5.3|120 / 90 |50 / 45|60 / 60 |-40&nbsp; -&nbsp; +80 |bestanden}}
{{Tab Sp2-9 center|[[INTELLO PLUS]]|110|E|5.3|350 N/50 mm / 290 N/50 mm|15% / 15% |240 N / 200 N |-40&nbsp; -&nbsp; +80 |bestanden}}
{{Tab Sp2-9 center|[[INTELLO PLUS]]|110|E|5.3|350 / 290|15 / 15 |240 / 200 |-40&nbsp; -&nbsp; +80 |bestanden}}
{{Tab Sp2-9 center|[[DB]]|180|E|-|>90 N/50 mm / >90 N/50 mm |5% / 5%|>80 N / >80 N|bis &nbsp; +40 <br /> dauerhaft|bestanden}}
{{Tab Sp2-9 center|[[DB]]|180|E|-|>90 / >90 |5 / 5|>80 / >80 |bis &nbsp;+40, <br /> dauerhaft|bestanden}}
{{Tab Sp2-9 center|[[DB+]]|185|E|-|550 N/50 mm / 300 N/50 mm |5% / 5%|70 N / 70 N |bis &nbsp; +40 <br /> dauerhaft|bestanden}}
{{Tab Sp2-9 center|[[DB+]]|185|E|-|550 / 300 |5 / 5 |70 / 70 |bis &nbsp;+40, <br /> dauerhaft|bestanden}}
{{Tab Sp2-10 center|[[INTESANA]]<br />[[INTESANA connect]]|140|E|-|250 N/50 mm / 170 N/50 mm |60% / 60% |120 N / 120 N |-40&nbsp; -&nbsp; +80 |bestanden|<sup>F2, Wd1, Ws, S</sup>}}
{{Tab Sp2-10 center|[[INTESANA]]<br />[[INTESANA connect]]|140|E|-|250 / 170 |60 / 60 |120 / 120 |-40&nbsp; -&nbsp; +80 |bestanden|<sup>F2, Wd1, Ws, S</sup>}}
{{Tab Sp2-10 center|[[DA]]<br />[[DA connect]]|130|E|-|230 N/50 mm / 190 N/50 mm|50% / 50% |90 N / 90 N |-40&nbsp; -&nbsp; +100 |bestanden|<sup>F3, Wd1, Ws</sup>}}
{{Tab Sp2-10 center|[[DA]]<br />[[DA connect]]|130|E|-|230 / 190 |50 / 50 |90 / 90 |-40&nbsp; -&nbsp; +100 |bestanden|<sup>F3, Wd1, Ws</sup>}}
{{Tab Sp2-9 center|[[DASATOP]]|90|E|-|195 N/50 mm / 105 N/50 mm |70% / 70% |110 N / 105 N |-40&nbsp; - +80 |bestanden}}
{{Tab Sp2-9 center|[[DASATOP]]|90|E|-|195 / 105 |70 / 70 |110 / 105 |-40&nbsp; - +80 |bestanden}}
{{Tab Sp2-9 center|[[SANTA DT]]<br />[[SANTA UT]]|185|E|-|-|-|-|bis &nbsp; +40 <br /> dauerhaft| }}
{{Tab Sp2-9 center|[[SANTA DT]]<br />[[SANTA UT]]|185|E|-|-|-|-|bis &nbsp;+40, <br /> dauerhaft| }}
{{Tab Sp2-9 center|[[RB]]|45|E|-|-|-|-|-40&nbsp; -&nbsp; +100 | }}
{{Tab Sp2-9 center|[[RB]]|45|E|-|-|-|-|-40&nbsp; -&nbsp; +100 | }}
|-
|-
Zeile 68: Zeile 68:
|colspan="10"| '''Winddichtung außen'''
|colspan="10"| '''Winddichtung außen'''
|-
|-
{{Tab Sp2-10 center|[[SOLITEX MENTO]]<br /> [[SOLITEX MENTO connect]]|110|E|-|205 N/50 mm / 170 N/50 mm|50% / 50%|100 N / 100 N |-40&nbsp; -&nbsp; +100 |bestanden|<sup>F3, Wd1, Ws, S</sup>}}
{{Tab Sp2-10 center|[[SOLITEX MENTO]]<br /> [[SOLITEX MENTO connect]]|110|E|-|205 / 170 | 50 / 50|100 / 100 |-40&nbsp; -&nbsp; +100 |bestanden|<sup>F3, Wd1, Ws, S</sup>}}
{{Tab Sp2-10 center|[[SOLITEX UD]]<br /> [[SOLITEX UD connect]]|140|E|-|270 N/50 mm / 200 N/50 mm |45% / 60%|130 N / 130 N|-40&nbsp; -&nbsp; +100 |bestanden|<sup>F3, Wd1, Ws, S</sup>}}
{{Tab Sp2-10 center|[[SOLITEX UD]]<br /> [[SOLITEX UD connect]]|140|E|-|270 / 200 |45 / 60|130 / 130 |-40&nbsp; -&nbsp; +100 |bestanden|<sup>F3, Wd1, Ws, S</sup>}}
{{Tab Sp2-10 center|[[SOLITEX PLUS]]<br /> [[SOLITEX PLUS connect]]|170|E|-|485 N/50 mm / 350 N/50 mm|15% / 15% |>350 N / >350 N |-40&nbsp; -&nbsp; +100 |bestanden|<sup>F3, Wd1, Ws, S</sup>}}
{{Tab Sp2-10 center|[[SOLITEX PLUS]]<br /> [[SOLITEX PLUS connect]]|170|E|-|485 / 350 |15 / 15 |>350 / >350 |-40&nbsp; -&nbsp; +100 |bestanden|<sup>F3, Wd1, Ws, S</sup>}}
{{Tab Sp2-10 center|[[SOLITEX UM connect]]|450|E|-|270 N/50 mm / 200 N/50 mm|45% / 60% |>130 N / >130 N |-40&nbsp; -&nbsp; +100 |bestanden|<sup>F3, Wd1, Ws</sup>}}
{{Tab Sp2-10 center|[[SOLITEX UM connect]]|450|E|-|270 / 200 |45 / 60 |>130 / >130 |-40&nbsp; -&nbsp; +100 |bestanden|<sup>F3, Wd1, Ws</sup>}}
{{Tab Sp2-10 center|[[SOLITEX WA]]|100|E|-|190 N/50 mm / 145 N/50 mm |80% / 85%|145 N / 110 N |-40&nbsp; -&nbsp; +100 |bestanden|<sup>F3, Wd2</sup>}}
{{Tab Sp2-10 center|[[SOLITEX WA]]|100|E|-|190 / 145 |80 / 85|145 / 110 |-40&nbsp; -&nbsp; +100 |bestanden|<sup>F3, Wd2</sup>}}
|}
|}



Version vom 3. März 2011, 21:29 Uhr

Übersicht technische Daten der pro clima Dichtungsbahnen

Daten der pro clima Bahnen unter Anderem für die Berechnung nach dem Glaser-Verfahren.

Dichte
[kg/m³]
Dicke
[mm]
WLF λ
[W/mK]
µ
[-]
sd-Wert
[m]
µ
Rechenwert
[-]
sd-Wert
Rechenwert
[m]
sd-Wert
feuchtevariabel
[m]
Luftdichtung innen nach
DIN 4108-3
Nicht für das
Glaser-Verfahren
INTELLO
INTELLO PLUS
500
550
0,20 0,17 37.500 7,50 37.500 7,50 0,25 - >10,00
DB
DB+
600
625
0,23 0,13 10.000 2,30 10.000 2,30 0,60 - 4,00
INTESANA
INTESANA connect
310 0,45 0,17 16.700 7,50 16.700 7,50 0,25 - >10,00
DA
DA connect
320 0,46 0,17 5.000 2,30 5.000 2,30 -
DASATOP 280 0,25 0,17 6.400 1,60 6.400 1,60 0,05 - 2,00
SANTA DT
SANTA UT
600 0,40 0,13 5.750 2,30 5.750 2,30 -
RB 600 0,30 0,13 100 0,03 333 0,10 -
Winddichtung außen
SOLITEX MENTO
SOLITEX MENTO connect
275 0,4 0,17 200 0,05 250 0,10 -
SOLITEX UD
SOLITEX UD connect
280 0,50 0,17 160 < 0,08 200 0,10 0,02 feuchtevariabel
SOLITEX PLUS
SOLITEX PLUS connect
310 0,55 0,17 145 < 0,08 182 0,10 0,02 feuchtevariabel
SOLITEX UM connect 63 8 0,17 10 < 0,08 12,5 0,10 0,02 feuchtevariabel
SOLITEX WA 222 0,45 0,17 22 0,01 222 0,10 -

Für alle Bahnen gilt: Spezifische Wärmekapazität: 1 J/(kg x k)


Die in einer Berechnung nach dem Glaser-Verfahren ermittelten Tauwasser- und Verdunstungsmengen verbessern sich bei feuchtevariablen Dampfbrems- und Luftdichtungsbahnen in der Realität erheblich. Feuchtevariable sd-Werte halten die Konstruktionen trocken und sorgen für bauschadensfreie Bauteile. Im Winter werden hohe sd-Werte erreicht und verhindern so bauteilschädigenden Feuchteeintrag. Im Sommer kann der sd-Wert im Bedarfsfall stark sinken und ermöglicht so eine rasche Austrocknung von Feuchtigkeit aus dem Bauteil heraus. Dadurch werden höchste Sicherheiten auch bei unvorhergesehenem Feuchteeintrag erreicht.

Weitere Werte

Flächen-gewicht
[kg/m²]
Brand- verh.
[-]
Brand-kennz.
n. VKF
Höchzugkraft
[N/50 mm]
längs / quer
Dehnung
[%]
längs / quer
Weiterreiß-widerstand [N]
längs / quer
Temperatur-beständigkeit
[°C]
Alterungs-beständigkeit
[-]
Luftdichtung innen
INTELLO 85 E 5.3 120 / 90 50 / 45 60 / 60 -40  -  +80 bestanden
INTELLO PLUS 110 E 5.3 350 / 290 15 / 15 240 / 200 -40  -  +80 bestanden
DB 180 E - >90 / >90 5 / 5 >80 / >80 bis  +40,
dauerhaft
bestanden
DB+ 185 E - 550 / 300 5 / 5 70 / 70 bis  +40,
dauerhaft
bestanden
INTESANA
INTESANA connect
140 E - 250 / 170 60 / 60 120 / 120 -40  -  +80 bestanden F2, Wd1, Ws, S
DA
DA connect
130 E - 230 / 190 50 / 50 90 / 90 -40  -  +100 bestanden F3, Wd1, Ws
DASATOP 90 E - 195 / 105 70 / 70 110 / 105 -40  - +80 bestanden
SANTA DT
SANTA UT
185 E - - - - bis  +40,
dauerhaft
RB 45 E - - - - -40  -  +100
Winddichtung außen
SOLITEX MENTO
SOLITEX MENTO connect
110 E - 205 / 170 50 / 50 100 / 100 -40  -  +100 bestanden F3, Wd1, Ws, S
SOLITEX UD
SOLITEX UD connect
140 E - 270 / 200 45 / 60 130 / 130 -40  -  +100 bestanden F3, Wd1, Ws, S
SOLITEX PLUS
SOLITEX PLUS connect
170 E - 485 / 350 15 / 15 >350 / >350 -40  -  +100 bestanden F3, Wd1, Ws, S
SOLITEX UM connect 450 E - 270 / 200 45 / 60 >130 / >130 -40  -  +100 bestanden F3, Wd1, Ws
SOLITEX WA 100 E - 190 / 145 80 / 85 145 / 110 -40  -  +100 bestanden F3, Wd2


Legende: Freibewitterung F2: 2 Monate F3: 3 Monate
Wasserdichtheit Wd1: W1 bestanden Wd2: W2 bestanden, regensicher
Wassersäule Ws: > 2.500 mm
Schlagregentest
gemäß ZVDH
S: bestanden


Der Verweis auf die jeweils bezogenen Normen findet sich auf den jeweiligen Produktseiten unter "Technische Daten".